Is your boiler pressure too low — or too high?

0.6 bar on a cold system means top it up with the filling loop, and ten minutes fixes it. 2.8 bar cold means the system is over-pressurised, and topping it up again will only make it worse. The same gauge, two opposite answers — and the difference is the number, whether the system was hot or cold, and whether the pressure will stay put. Answer nine questions and this checker gives you the verdict — your pressure is fine, top it up yourself, book an engineer, or call one now — free, in your browser, nothing uploads.

  • 1–1.5 bar when cold is normal
  • Below 1 bar? Top it up
  • Over 2.5 bar? Call an engineer
  • Free, no account, nothing uploads
Boiler pressure checker: find out whether your gauge reading is too low, fine, or too high.

Check whether your boiler pressure is OK

Try a preset:
0 of 9 answered

Your result

Answer the questions Your verdict appears here as you answer.
Recommended action

Answer the questions above and the recommended action will appear here.

Blockers

Things that do not fit

Things to check

Still to confirm

What to do next

    Your result summary

    
              

    Answer the questions above — the verdict updates live.

    Privacy you can verify, not just trust

    Checking what your boiler pressure means by uploading your home's details to a website would be backwards — the check should never be the leak. This one can't: your answers are checked with plain JavaScript on your device, and they never leave the device — the only third-party requests are the site's own analytics, which count page views. Don't take our word for it:

    New cross-origin requests during use: 0
    1. Press F12 to open developer tools, then the Network tab.
    2. Answer a question above. Watch: apart from the site's analytics, nothing new is requested — no uploads, and no data ever leaves your device.
    3. Extra credit: disconnect your internet after this page loads — the checker still works.

    How the boiler pressure check works

    Boiler pressure is the pressure of the water inside your sealed central heating system. It is measured in bar and shown on a dial or a digital display on the front of the boiler. When the system is cold, the pressure should usually sit between 1 and 1.5 bar. When the heating has been running and the water is hot, it may rise to between 1.5 and 2 bar, which is normal. Pressure below 1 bar is generally too low — many modern boilers will show a fault code or lock out at very low pressure, which is why the heating or hot water can stop without warning. Pressure that climbs above 2.5 to 3 bar is too high and can cause water to be released through the safety valve. The number on its own is not the whole story, though: the same reading means something different on a hot system than a cold one, a one-off fall after bleeding the radiators is expected, and a fall that comes back every day means water is leaving the system somewhere. This checker weighs all of it — the reading, whether the system was hot or cold, what kind of boiler it is, the symptoms, how often the pressure drops, any recent work, the boiler's age, visible water, and what the needle does while the heating runs — and gives you a verdict: your pressure is fine, top it up yourself, book a heating engineer, or call one now, with the steps for whichever one it is.

    To use it:

    1. Enter the gauge reading. Look at the gauge on the front of the boiler: on older boilers it is a round dial with a needle, on newer models it is a number on a digital display, sometimes shown after pressing an information button. Enter the number in bar, or switch to psi if your gauge reads psi (1 bar is about 14.5 psi). If your boiler has no gauge at all, tick the box — a regular boiler with a loft tank has no gauge, and the tank is the thing to check.
    2. Say whether the system was hot or cold. A cold reading is the useful one: the heating should have been off for at least an hour. A hot system reads higher than a cold one, because water expands as it heats up — so 1.8 bar hot can be fine, while 1.8 bar cold is a little high.
    3. Say what kind of boiler it is. A combi boiler has no tank. A system boiler has a hot-water cylinder. A regular boiler has a loft tank. A heat pump is not a boiler at all, and runs at lower pressures, so the 1 to 1.5 bar range does not apply to it. An oil boiler needs an OFTEC-registered technician, not a Gas Safe engineer.
    4. Say whether there are other symptoms. Radiators only partly warm, or cold in places, usually means trapped air or sludge — and low pressure lets air collect. No heating or hot water with low pressure is often the boiler protecting itself: it will not fire until the pressure is back up. A boiler that locks out is protecting itself from a fault. Water leaking, or a smell of gas, makes it urgent.
    5. Say how often the pressure drops. A one-off fall after bleeding is expected. A fall every few days means water is leaving the system somewhere — a slow leak, a weeping relief valve, or a tired expansion vessel. A pressure that keeps dropping even after topping up is the clearest sign of a leak: topping it up again only buys a few days.
    6. Say whether there has been recent work. Bleeding radiators lets water out as well as air, so the pressure falls — that is expected, not a fault, and topping it back up is the normal next step. A new boiler with the wrong pressure is not normal: call the installer back, because it is under warranty.
    7. Say how old the boiler is. Under 5 years old, a pressure fault is likelier to be the filling loop, a valve, or the installation than wear. Over 15 years old, the expansion vessel, the relief valve and the pipework are all old enough to be the cause of a pressure that will not hold.
    8. Say whether there is visible water. Water dripping from the overflow pipe outside means the pressure relief valve is releasing water because the pressure is too high. Damp patches on walls, ceilings or floors can be a slow leak from the heating pipework — and a slow leak is why the pressure keeps falling. Water under or around the boiler can damage the electrics inside it.
    9. Say what the needle does while the heating runs. A needle that rises a little and settles back is normal. A needle that climbs sharply every time the heating comes on points at the expansion vessel, the part that absorbs the extra pressure as water heats up. A needle that falls while the heating runs means water is leaving the system while it is hot — a leak that only shows under pressure.

    The five verdicts, and what each one means

    Your pressure is fine

    About 1 to 1.5 bar when cold, or 1.5 to 2 bar when hot, and nothing else wrong. No repair is needed. Check the gauge once a month: a slow fall over weeks is the earliest sign of a leak.

    Top it up yourself

    Below 1 bar when cold, and the pressure has never dropped before — or it fell because you bled the radiators. Switch the heating off, let the boiler cool, open the filling-loop valves slowly, watch the gauge, and close both valves firmly at 1 to 1.5 bar. Never open the boiler casing.

    Book a heating engineer

    The pressure keeps dropping, it is too high, the needle climbs sharply, or the overflow pipe outside is dripping. The cause is inside the system — a leak, a faulty relief valve, or the expansion vessel — and only an engineer may open the casing.

    Call an engineer now

    A smell of gas, water leaking inside, pressure over 3 bar, or a boiler that keeps locking out. Stop using the boiler. If you smell gas, open the windows, leave the house, and call the gas emergency number from outside (UK: 0800 111 999).

    Cannot tell yet

    Not enough answers to judge: without the gauge reading, 0.6 bar cold means top it up, 2.8 bar cold means call an engineer, and 1.2 bar cold means carry on — and the checker cannot tell which one yours is. Read the gauge when the system is cold and the verdict appears.

    What makes this checker different

    The pages that rank for this search are guides — a manufacturer's page on what the pressure should be, a plumber's guide to topping it up, a heating site's table of readings and meanings. None of them asks what your gauge reads, whether the system was hot or cold, how often the pressure drops, or what the needle does while the heating runs — and none of them gives you a verdict for your boiler. They all assume you already know which reading you have, which is exactly the question people are asking. This page is that answer: nine questions, an instant verdict, the blockers named, and the next steps. It is a self-assessment, so it says plainly what it cannot know: it cannot read your pressure gauge, hear your boiler, or smell gas.

    When is this the right check?

    When the heating comes on for the winter and the boiler shows a fault code, or the radiators are only partly warm — because low pressure is the first thing to check, and it takes a minute to read the gauge. When you have just bled the radiators — because bleeding drops the pressure, and the checker tells you whether to top it up or call an engineer. When the pressure keeps falling no matter how often you top it up — because that is a leak, a faulty relief valve, or the expansion vessel, and topping it up again only buys a few days. And when you can smell gas near the boiler — because that is an emergency, and the checker will tell you to leave the house and call the gas emergency number before anything else.

    Honest limitations

    A self-assessment, not an engineer's diagnosis

    This checker cannot read your pressure gauge, hear your boiler, or smell gas. It cannot tell whether a fall is a leak or a faulty relief valve, or whether a high reading is the filling loop or the expansion vessel. If the pressure keeps dropping, the boiler locks out, anything leaks, or you smell gas, call a heating engineer.

    Without the reading, the verdict is weaker

    What the gauge reads is the single most useful answer: 0.6 bar cold means top it up, 2.8 bar cold means call an engineer, and 1.2 bar cold means carry on — and the three need opposite responses. The checker still works without it, but it says so — the verdict drops to low confidence and the first step is to read the gauge when the system is cold.

    Pressure figures are typical, not your boiler's exact ones

    About 1 to 1.5 bar when cold is the range most manufacturers ask for, and 1 bar is about 14.5 psi. Your boiler manual's figures beat this page's: use them if you have them, especially if your boiler is a heat pump or an older regular boiler with a loft tank.

    Guides disagree on the exact high-pressure line

    Some guides call 2 bar cold too high; others say up to 2 bar is acceptable on some systems, and Vaillant advises avoiding pressure above 2.5 bar. This checker says 2 bar cold needs an engineer, and over 3 bar is urgent — but if your boiler manual says otherwise, follow the manual: it knows your system.

    Steam systems are not covered

    Older US homes with steam heat have air vents on the radiators, not bleed valves, and a sight glass on the boiler instead of a pressure gauge. The advice here is for hot-water (hydronic) systems. If your radiators have a chrome vent on one side and only one pipe, do not use this checker — call a heating technician who knows steam.

    Rules from official sources, dated November 2026

    The rules here are manufacturer guidance, including British Gas on the 1 to 1.5 bar range, Vaillant on the 2.5 bar line, and Viessmann on the 1 bar figure, as they read in November 2026. Guidance changes: recheck with a heating engineer if anything about the system changes.

    Frequently asked questions

    What should my boiler pressure be?

    About 1 to 1.5 bar when the heating is cold — the range most manufacturers ask for (about 12–22 psi on a US gauge; 1 bar is about 14.5 psi). British Gas and Vaillant both give 1 to 1.5 bar cold, and Viessmann says a boiler that is off should sit at approximately 1 bar. When the heating has been running and the water is hot, the reading may rise to between 1.5 and 2 bar, which is normal. Below 1 bar is too low, and the boiler may lock out. Above 2 bar when cold is too high, and above 2.5 bar even when hot means turn the boiler off and call an engineer. Regular boilers with a loft tank have no gauge — the tank tops the system up itself.

    Is 0.5 bar too low for a boiler?

    Yes — 0.5 bar is too low. Most sealed systems should read about 1 to 1.5 bar when cold, and below 1 bar the boiler may lock out or show a fault code, which is why the heating or hot water can stop without warning. Top the system back up to about 1 to 1.5 bar with the filling loop: heating off and cool, open the valves slowly, watch the gauge, stop at 1 to 1.5 bar, close both valves firmly. Then watch the gauge over the next few days: if it holds, it was a one-off; if it keeps dropping, there is a leak, a faulty pressure relief valve, or a problem with the expansion vessel, and that needs an engineer.

    How do I top up my boiler pressure?

    Most combi and system boilers have a filling loop, a short flexible hose under the boiler with one or two small valves. Switch the heating off and let the boiler cool — a cold reading is the useful one. Find the filling loop, open one valve slowly, then the other: you should hear water entering the system. Watch the pressure gauge as you do this. When the gauge reaches 1 to 1.5 bar, close both valves firmly, one after the other. Then check the pressure again over the next few days: if it keeps dropping, there is a leak somewhere. Never open the boiler casing — anything inside it is an engineer's job — and if your boiler manual says something different, follow the manual.

    Why does my boiler keep losing pressure?

    A system that keeps losing pressure usually has a leak, a faulty pressure relief valve, or a problem with the expansion vessel, which is the part that absorbs the extra pressure as water heats up. Bleeding radiators also lowers the pressure, because it lets water out as well as air — so a fall after bleeding is expected, not a fault. Check the overflow pipe outside for drips: the relief valve releasing water is the commonest invisible exit. If the gauge climbs sharply every time the heating comes on, that points at the expansion vessel. Topping the system up again only buys a few days: finding where the water goes is the engineer's job.

    Is high boiler pressure dangerous?

    High pressure is a problem, but the system has a safety valve for it. Above 2 bar when cold is too high, and the pressure relief valve may start dripping. Above 2.5 bar even when hot means turn the boiler off and call an engineer — Vaillant advises avoiding pressure above 2.5 bar. The relief valve releases water at around 3 bar, so over 3 bar is past the point the valve should have opened, and that is urgent: turn the boiler off and call an engineer now. Do not add more water, and do not bleed radiators to bring the pressure down yourself.

    What should I do if I smell gas near my boiler?

    Treat it as an emergency. Do not switch anything electrical on or off — including light switches and phones — and do not light anything. Open the windows, turn the gas off at the meter if you can do so safely, leave the house, and call the gas emergency number from outside (in the UK: 0800 111 999). In the US, call your gas utility's emergency line or 911. Do not go back inside until you are told it is safe, and do not try to find the leak yourself. Only a Gas Safe registered engineer (UK) or a licensed technician may work on a gas boiler.

    Does this checker replace a heating engineer?

    No. This checker is a self-assessment: it runs your answers against manufacturer guidance, including British Gas, Vaillant and Viessmann, as it reads in November 2026, entirely in your browser, and nothing you enter leaves your device. A web page cannot read your pressure gauge, hear your boiler, or smell gas. If the boiler locks out, anything leaks, the pressure keeps dropping, or you smell gas, call a heating engineer — and never open the boiler casing yourself. The only third-party requests are the site's own analytics, which count page views.